Ducted air conditioning repairs in Auckland

One fan coil in the ceiling, ducts out to every room, and a wall controller that runs the lot. When a ducted system plays up, the whole floor notices. We find out why.

Since 2012
Heat pump and air conditioning repairs in central and south Auckland
Electrical side
Faults in the boards, sensors, wiring and power supply
Main brands
Mitsubishi Electric, Fujitsu, Panasonic, Daikin, Toshiba, Hitachi
Business areas
Penrose to Papakura, Newmarket to East Tāmaki

How a ducted system goes wrong

A ducted system hides most of itself above the ceiling, so the first sign is a room that won’t come right while the rest do.

The pattern tells us where to look. One room points to its zone. The whole floor points to the fan coil, the outdoor unit or the power to them.

  • One zone or room getting no air
  • Air moving everywhere but not cooling or heating
  • Weak airflow at every grille
  • Water through a ceiling tile near the fan coil
  • A code on the wall controller
  • The system starts, then shuts down
Roof / outside wallOpen-plan officeMeeting roomManagerKitchenComms roomReceptionBreakoutToiletsCEILING PLAN · OFFICE FLOOR (EXAMPLE)!Roof / outside wallOpen-plan officeMeeting roomManagerKitchenComms roomReceptionBreakoutCEILING PLAN · OFFICE FLOOR (EXAMPLE)!

Office floor · example: 2 ceiling cassettes, 2 ducted systems, 2 outdoor units, 1 playing up.

Dead zones and dampers

Each zone has a damper in the duct, driven by a small motor and told what to do by the zone controller. A stuck damper or a failed motor leaves one room still while the rest run.

Tell us which rooms are affected and what the controller shows for each zone.

The wired controller is where the codes show. Note the code, and the brand, before anyone resets the system.

Fan coil, drain and controls

The fan coil in the ceiling space carries the fan, the coil, the drain tray and the board. Weak airflow everywhere can be the fan or a blocked return air filter; water through a tile is the drain.

We see ducted systems from Daikin, Mitsubishi Electric, Fujitsu, Panasonic, Toshiba, Hitachi and Temperzone, often with cassettes and high-wall splits on the same site.

What to have ready

Access to the ceiling
Where the fan coil sits, and whether there’s a hatch near it.
The outdoor unit
Roof, wall or ground, and how we reach it.
The zones
Which rooms are affected and which are fine.
The label
Brand and model, off the outdoor unit or the fan coil.

We find the fault, then agree the repair with you once we know what it needs.

Ducted system questions

Not covered here? Call 0800 211 408 or send us the unit list.

Do you work on commercial ducted systems?

Yes. Ducted systems in offices, shops and schools, from the fan coil and ducts to the zone dampers, the controller and the outdoor unit.

Only one room has no air. Is it the whole system?

Not often. One dead room points to that zone’s damper, its motor or the zone controller. Tell us which room and what the controller shows.

Can you check a ducted system that runs but feels weak?

Yes. Book a one-off service and we check airflow at each grille, the fan, the return air, the dampers and the controls.

Tell us about the ducted system

Put the ducted system in Units on site, say which zones are affected in the message and add the code from the controller. We ring back to sort a time.

Call 0800 211 408

What saves a second trip

  • How many units, of which type, and which are down
  • The brand and model off the label on each faulty unit
  • Any code on the wall controller or remote
  • Where the outdoor units sit and how we reach them
  • Who meets us, and when the room is free